Technician inspecting a residential solar system
All common solar issues

Solar System Keeps Going Offline

"Offline" in a monitoring app can mean two very different things: the system stopped producing, or only the reporting stopped. Knowing which one you have changes everything about what to do next.

Two meanings of offline

If every panel is missing from the app at once, the problem is almost always communications or the inverter. If one or two panels are missing while the rest report normally, that points to those specific units. That single observation is the most useful thing you can tell a technician.

Why grid-tied systems shut down

A grid-tied inverter must shut down when the grid goes down, to protect utility workers. If the neighbourhood lost power, the system going offline is expected rather than broken.

What we check

We separate a communications fault from a production fault first, because the two have completely different costs. A gateway problem is a small fix; a failed inverter is a replacement.

How long is too long to be offline?

A brief dropout after a power cut or a router restart is normal and usually resolves itself. A system showing no data for more than a few days is a different matter. Even if the system is producing, you are blind to any new problem, and a fault that starts during that window goes unnoticed. Restoring monitoring is worth doing for that reason alone.

Why restarts are not the answer

Repeatedly power-cycling a system that keeps dropping offline does not fix the cause, and on some hardware it obscures the fault history a technician would otherwise use. If a restart brings it back temporarily and it drops again, note how long it stayed up — that interval is itself diagnostic information.

When monitoring can never be restored

In a small number of cases the original monitoring hardware is obsolete or the platform has been discontinued. Where that happens, the practical answer is usually a replacement monitoring solution rather than a repair. We will say so plainly rather than billing for attempts that will not succeed.

Likely Causes, in the Order We Check Them

1

Internet or router problem

The monitoring gateway has lost its network connection. The commonest cause by far, and the system is usually still producing.

2

Failed monitoring gateway

The communications hardware itself has failed while the solar system continues working normally.

3

Inverter shutdown

The inverter has stopped — fault, overheat, or grid issue — and therefore has nothing to report.

4

Grid event or outage

A utility interruption caused the inverter to shut down, as grid-tied systems are designed to do.

What You Can Check Yourself

Check whether your utility usage still drops during daylight hours
Reboot your home router and see whether the app reconnects
Note whether the app shows a whole-system gap or individual panels missing
Check for a status light on the inverter itself

None of this requires going on the roof. Anything involving the array itself is best left to a technician.

Still Not Working?

We diagnose and repair existing systems across Napa, Sonoma, Marin, Solano and Contra Costa counties.

Call (707) 346-5480